AC Current 20A /200A/1800A 80mmφ CT
Model M-1800

FEATURES

  • 80mmφCT window and wide AC current measurements from 0.1A to 1000A.
  • DCmV analog data output for recorder.
Catalog PDF
SPECIFICATIONS
Measuring method:Dual slope integration mode
Display:3.5 digit LCD max. reading of 1999
Accuracy:23℃±5℃ 80%RH or less (50/60Hz)
RangeResolutionAccuracy
AC 20A10mA±3.0% rdg ± 3 dgt
AC 200A0.1A
AC 1800A1A
Jaw opening capability:80mmφ
Over range indication:Blanking of all digits except MSD 1
Low battery indication:"B" mark on LCD
Data hold indication:“D・H“ mark on LCD
Sampling:2 times/sec
Data output:DC100mV (for full scale)
Limitation of circuit voltage:Less than AC 600V
Withstanding voltage:AC 2000V 1 minute max. (Between the core of CT and outer case)
Operating temperature:0℃ to 40℃ 80%RH max. ( Without condensation )
Storage temperature:-10℃ to 60℃ 70%RH max. ( Without condensation )
Power supply:1.5V (AM-4 LR03 or AAA)×2
Power consumption:3 mW
Battery life:Approx. 350 hours( Alkaline batteries)
Size:138(W)×225(H)×37(D)mm
Weight:Approx. 500g
Accessories:
Hard carrying case:1
Instruction manual:1
Batteries:2